2.2 Basic Module

2.2.6 SVR Virtual Motion Module

2-50

( 4 ) SVR Operation

[ a ] SVR Execution Timing

The SVR is processed at the beginning of the high-speed scan. SVR processing is performed in the next scan after
specifying and the processing results are reflected in the monitoring parameters.

[ b ] Processing Time

When fixed parameter 0 (Selection of Operation Modes) is set to 0 (Normal Operation Mode), services are started for
each of the 16 SVR Module virtual axes.

Œ

The default for the Selection of Operation Modes parameter is 1 (Axis Unused).

The following table gives guidelines for the processing time required for each SVR axis.

Œ

Number of axes: The number of axes (1 to 16) when Selection of Operation Modes (fixed parameter 0) is set to Nor-
mal Operation Mode (0). The formula listed above do not apply when the number of axes is 0.

„

Differences from SVB Simulation Mode

Simulation mode does not have a positioning function, so the position data is refreshed in one scan to the final target position.
The SVR has its own positioning function that performs distribution, so like a real module, position data is refreshed each scan
for the final target position.

SVR

SVR

SVR

High-speed scan

H Drawing

Results of commands in the H
drawing are used in SVR
processing the next scan.

H Drawing

H Drawing

SVR processing results
can be monitored in the H
drawing of the same scan.

Reflected in monitoring
parameters

Reference set

SVR processing

Command

MP2300S

NOP

35 +14

× Number of axes (μs)

POSING

35 +36

× Number of axes (μs)