6.2 Communication with Other MP Series
6.2.2 When the MP2300S Acts as Slave (ladder program which uses a MSG-RCV function)
6-21
Built-in Ethernet Communications
Caution
When message functions (MSG-SND, MSG-RCV) are used with the connection number 01, disable the automatic receive func-
tion. If message functions are used while the automatic receive function is enabled, communications will not function properly.
Note: The automatic receive function with a connection number 01 is set to “Enable” by default.
5.
Click Yes in the parameter setting confirmation dialog.
Caution
Note that when a parameter with the same connection number is already set and you click Yes in the parameter setting confirma-
tion dialog, the setting will be overwritten by the parameter configured in the Message Communication Easy Setting Window.
6.
Check the setting values.
Caution
When any transmission or connection parameter is changed, the change will be reflected after FLASH has been saved and the
power supply is turned ON again.