6.3 Communication with Touch Panel

6.3.1 When the MP2300S Acts as Slave (automatic receive function is used)

6-71

Built-in Ethernet Communications

„

Port Number

• If you don’t check Automatic Assignment of the port number in the communication setting screen, the automatic assignment

will be disabled, and the GP3000 series port number will be fixed at the setting value.

• If you check Automatic Assignment of the port number in the communication setting screen, automatic assignment will be

enabled, and the GP3000 series port number will be assigned in each case.
When you use Automatic Assignment, set Unpassive open mode in the 218IFA screen of MPE720.
For more information about Unpassive open mode, refer to 2.2.4 (b) 218IFA Module Detailed Window .
For information on the relationship between GP-Pro EX and MPE720 settings, see the table below.

Note:

√: connectable, – : unconnectable

• How to set up Unpassive open mode of the MP2300S (reference)

Set Node IP Address to 000.000.000.000 and the Node Port to 0 to enter into the Unpassive open mode.

MPE720 Side Setting

GP-Pro EX Side Setting

Unpassive open

Mode

Fixed Value

Setting

Automatic Assignment Enable

Automatic Assignment Disable