Yaskawa MP2300S Basic Module User Manual
Page 130

4.5 Starting Motion Program from an External Signal
4.5.2 Required Equipment
4-14
Mapping of the touch panel manufactured by Digital Electronics Corp.
Note: 1. You do not need to create a program for signals and data in
c
to
i
.
2. You need to create a sequence program for outputting signals of
j
and
k
to the motion parameters.
3. For information on creating a program for the panel side, refer to 6.3 Communication with Touch Panel.
No.
Name
Mapping
Category
Description
MP2300S
Operation
c
Start
MB5000
Control signal
Starts up a motion program
Sets in M-
EXECUTOR
d
Stop
MB5002
Control signal
Displays the running of a motion program
e
Clear Alarm
MB5005
Control signal
Stops a motion program
f
Running Program
MB5010
Status
Clears an alarm of a motion program
g
Alarm
MB5018
Status
Indicates an alarm is occurring in a motion
program
h
Axis 1
(current position)
IL8016
Monitor parameter
Displays current axis 1 position
Automatic
receive function
i
Axis 2
(current position)
IL8096
Monitor parameter
Displays current axis 2 position
j
Servo (ON/OFF)
MB5020
External signal
Axis 1, axis 2 servo ON signal
Sequence pro-
gram is needed
k
Reset Axis Alarm
MB5021
External signal
Axis 1, axis 2 alarm reset signal