Yaskawa MP2300S Basic Module User Manual

Page 130

Advertising
background image

4.5 Starting Motion Program from an External Signal

4.5.2 Required Equipment

4-14

Mapping of the touch panel manufactured by Digital Electronics Corp.

Note: 1. You do not need to create a program for signals and data in

c

to

i

.

2. You need to create a sequence program for outputting signals of

j

and

k

to the motion parameters.

3. For information on creating a program for the panel side, refer to 6.3 Communication with Touch Panel.

No.

Name

Mapping

Category

Description

MP2300S
Operation

c

Start

MB5000

Control signal

Starts up a motion program

Sets in M-
EXECUTOR

d

Stop

MB5002

Control signal

Displays the running of a motion program

e

Clear Alarm

MB5005

Control signal

Stops a motion program

f

Running Program

MB5010

Status

Clears an alarm of a motion program

g

Alarm

MB5018

Status

Indicates an alarm is occurring in a motion
program

h

Axis 1
(current position)

IL8016

Monitor parameter

Displays current axis 1 position

Automatic
receive function

i

Axis 2
(current position)

IL8096

Monitor parameter

Displays current axis 2 position

j

Servo (ON/OFF)

MB5020

External signal

Axis 1, axis 2 servo ON signal

Sequence pro-
gram is needed

k

Reset Axis Alarm

MB5021

External signal

Axis 1, axis 2 alarm reset signal

Advertising