6.2 Communication with Other MP Series

6.2.2 When the MP2300S Acts as Slave (ladder program which uses a MSG-RCV function)

6-24

„

Parameter list setting example for message receive function

An example of a parameter list setting when receiving messages from a transmit source using the connection with
a connection number = 2 follows:

Note: IN: Input, OUT: Output, SYS: For system use

Table 6.5 Parameter List Setting Example (parameter list start address Param=DA00000)

Register

Number

Setting

Value

Parameter

Number

IN/OUT

Remarks

DW00000

PARAM00

OUT

Process result

DW00001

PARAM01

OUT

Status

DW00002

00002

PARAM02

IN

Connection number = 2

DW00003

PARAM03

OUT

Option

DW00004

PARAM04

OUT

Function code

DW00005

PARAM05

OUT

Data address

DW00006

PARAM06

OUT

Data size

DW00007

PARAM07

OUT

Remote CPU number

DW00008

00000

PARAM08

IN

Coil offset = 0 word

DW00009

00000

PARAM09

IN

Input relay offset = 0 word

DW00010

00000

PARAM10

IN

Input register offset = 0 word

DW00011

00000

PARAM11

IN

Holding register offset = 0 word

DW00012

00000

PARAM12

IN

Writable address lower limit = MW00000

DW00013

65534

PARAM13

IN

Writable address upper limit = MW65534

DW00014

PARAM14

SYS

Reserved by the system. (Zero clear at startup)

DW00015

PARAM15

SYS

Reserved by the system.

DW00016

PARAM16

SYS

Reserved by the system.