Appendix G MSG-SND/MSG-RCV Functions (Ethernet)

G.1 Message Transmit Function (MSG-SND)

A-65

Appendices

( 9 ) Remote CPU Number (PARAM07)

Set a remote CPU number.
When the remote device is MP2000 series, specify “1”.
When the remote device is a controller manufactured by YASKAWA Electric Corporation, but other than the MP2000
series, and comprises multiple CPU modules, specify the destination CPU number.
Otherwise, specify “0”.

( 10 ) Offset (PARAM08 to PARAM11)

Specify the offset addresses of read data storage areas and write data source of the transmission side.
The address for the transmission side will be displaced by the number of words designated by the offset.

Note: 1. For more information, refer to G.1.8 Relationship between Data Address, Data Size, and Offset for

MSG-SND Function.

2. The offset cannot be a negative value.

The offset parameter is prepared for each target data type.
The following table lists the offset parameters.

The valid offset parameter may differ, depending on the function code.
The following table provides the valid parameters for each function code.

Note:

√: Available, –: Not available

Table G.4 Offset Parameter List

Parameter

Content

Description

PARAM08

Coil offset

Sets the coil's offset word address.

PARAM09

Input relay offset

Sets the offset word address of an input relay.

PARAM10

Input register offset

Sets the offset word address of an input register.

PARAM11

Holding register offset

Sets the offset word address of a holding register.

Table G.5 Valid Parameter List for Offset of Each Function Code

Function

Code

Function

Valid Offset

Parameter

Protocol Type

Extended

MEMOBUS

MEMOBUS

01H

Reads coil state

PARAM08

02H

Reads input relay state

PARAM09

03H

Reads holding register content

PARAM11

04H

Reads input register content

PARAM10

05H

Changes single coil state

PARAM08

06H

Writes to single holding register

PARAM11

09H

Reads holding register content (extended)

PARAM11

0AH

Reads input register content (extended)

PARAM10

0BH

Writes to holding register (extended)

PARAM11

0DH

Discontinuously reads holding register
(extended)

PARAM11

0EH

Discontinuously writes to holding register
(extended)

PARAM11

0FH

Changes multiple coil states

PARAM08

10H

Writes to multiple holding registers

PARAM11

Advertising