Appendix E Motion Parameter Details

E.2 Setting Parameter List

A-40

OW††09

Motion Command
Control Flag

Bit 0: Holds a Command. (0: OFF/1: ON)

Yes

Yes

Bit 1: Interrupt a Command. (0: OFF/1: ON)

Yes

Yes

Bit 2: Moving Direction (JOG/ STEP)

(0: Forward rotation/1: Reverse rotation)

Yes

Yes

Bit 3: Zero Point Return Direction Selection

(0: Reverse rotation/1: Forward rotation)

Yes

Bit 4: Latch Zone Effective Selection (0: Disabled/1: Enabled)

Yes

Bit 5: Position Reference Type

(0: Incremental Addition Mode/1: Absolute Mode)

Yes

Yes

Bit 6: Phase Compensation Type

(0: Incremental Addition Mode/1: Absolute Mode)

Yes

Bits 7 to F: Reserved

OW††0A Motion Subcommand

0: NOP (No Command)

Yes

Yes

1: PRM_RD (Read User Constant)(Read SERVOPACK Parameter)
2: PRM_WR (Write User Constant)(Write SERVOPACK Parameter)
3: Reserved
4: SMON (Status Monitor)

Yes

5: FIXPRM_RD (Read Fixed Parameters)

Yes

Yes

OW††0B

Reserved

OL††0C

Torque/Thrust
Reference Setting

Unit is according to OW††03, bits 12 to 15 (Torque Unit).

Yes

Yes

OW††0E

Speed Limit Setting
at the Torque/Thrust
Reference

1 = 0.01% (percentage of rated speed)

Yes

OW††0F

Reserved

OL††10

Speed Reference
Setting

Unit is according to OW††03, bits 0 to 3 (Speed Unit).

Yes

Yes

OW††12

to

OW††13

Reserved

OL††14

Positive Side Limiting
Torque/Thrust
Setting at the Speed
Reference

Unit is according to OW††03, bits C to F (Torque Unit).

Yes

OL††16

Secondly Speed
Compensation

Unit is according to OW††03, bits 0 to 3 (Speed Unit).

Yes

Yes

OW††18 Override

1 = 0.01%

Yes

OW††19

to

OW††1B

Reserved

OL††1C

Position Reference
Setting

1 = 1 reference unit

Yes

Yes

OL††1E

Width of Positioning
Completion

1 = 1 reference unit

Yes

OL††20

NEAR Signal Output
Width

1 = 1 reference unit

Yes

OL††22

Error Count Alarm
Detection

1 = 1 reference unit

Yes

OL††24

Reserved for system use.

OW†26

Position Complete
Cheek Time

1 = 1 ms

Yes

OW††27

Reserved for system use.

OL††28

Phase Correction
Setting

1 = 1 reference unit

Yes

OL††2A

Latch Zone Lower
Limit Setting

1 = 1 reference unit

Yes

(cont’d)

Register No.

Name

Contents

SVB SVR