2.2 Basic Module

2.2.4 218IFA Module (Ethernet)

2-20

„

Message Communication Item of Connection Parameter Setting

Sets the connection parameters for the message communication using MSG-SND/MSG-RCV function and the
message communication using automatic receive function.

The following table shows each setting item.

Item

Setting Range

Details

Default

Easy Setting

Opens the easy setting screen for the connection parameters. The
content of the selected connection is shown.

Connection Number
(CNO)

1 to 4

In 218IFA Ethernet communication, remote stations are distin-
guished by their connection numbers.
This connection number is used in remote connection number
(PARAM02) of the parameter list (PARAM) of the MSG-SND/
MSG-RCV function.

Local Port

256 to 65535

Specify the 218IFA port number for each connection. The 218IFA
module establishes a message communication with the connection
with this port number only. Set an unique channel number for the
port number of this connections.
Also, to delete the port number, enter zero.
Note: When the connection type = UDP, the port number cannot be

9998 or 10000.

0

Node IP Address

0.0.0.0 to

255.255.255.254

Set the remote IP address for each connection. However, the fol-
lowing addresses are excluded:

127.xxx.xxx.xxx
xxx.xxx.xxx.000 (except 000.000.000.000)
xxx.xxx.xxx.255

Note: When 0.0.0.0 is set, it will enter into “Unpassive open

mode.” When the 218IFA module is within the network
specified by the subnet mask, it responds to the connection
request from the remote station regardless of the remote IP
address setting.

000.000.000.0

00

Node Port

0 and

256 to 65535

Specify the remote port number for each connection. A pair of
remote IP address and remote port number must not be duplicated.
Note: In case of “Unpassive open mode,” set it to zero.

0

Connect Type

TCP,
UDP

Select a transport layer protocol.

TCP: Transmission control protocol
UDP: User datagram protocol

TCP

Protocol Type

Extended

MEMOBUS,
MEMOBUS,

MELSEC,

None,

MODBUS/TCP

Select an application layer protocol.

Extended

MEMOBUS

Protocol Type

Overview

Extended
MEMOBUS

Yaskawa’s Extended MEMOBUS protocol.

MEMOBUS

Yaskawa’s MEMOBUS protocol.

MELSEC

Ethernet I/F protocol for the sequencer (A
series) manufactured by Mitsubishi Elec-
tric Corporation.

Non-procedure

General-purpose message communication.
Transmits and receives continuous data
intact in the specified register.

MODBUS/TCP

Industrial Ethernet protocol proposed by
Modicon, Inc.