6.2 Communication with Other MP Series

6.2.1 When the MP2300S Acts as Slave (automatic receive function is used)

6-6

4.

Set a communication setting in the Message Communication Easy Setting Window.

„

How to set up in the Message Communication Easy Setting Window

c When automatic receive is used, select “1” for the Connect No.
d Set Port No. of the MP2300S side (“10001,” for example).
e Select Extended MEMOBUS for the Communication Protocol Type, and click Default Button.
f Select Connect Type (TCP, for example).
g Select Code (BIN, for example).
h Set Node Port IP Address for the other device (MP2300) to be connected (“192.168.001.002,” for example).
i Set Port No. of the other device (MP2300) to be connected (“10001,” X for example).
j Click OK Button.

„

Caution

When message functions (MSG-SND, MSG-RCV) are used with the connection number 01, disable the automatic receive func-
tion. If message functions are used while the automatic receive function is enabled, communications will not function properly.

Note: The automatic receive function with a connection number 01 is set to “Enable” by default.