Appendix H Optional Functions

H.1 Clearing D Registers at Startup

A-120

Appendix H Optional Functions

H.1

Clearing D Registers at Startup

( 1 ) Overview of Functions

D registers are internal registers that are unique for each user program. Normally, the D register data that is stored in
flash memory is restored for a flash startup, but it is also possible to start with the data cleared. Specifically, The data
cleared by this function is the D registers of DWG (drawings), user functions, and motion programs. Make the settings
in the System Setting of the Environment Setting Dialog Box. With the default settings, the D registers will not be
cleared at startup.

( 2 ) Supported Versions

The following versions support function to clear D registers at startup.

• Controller: Version 2.32 or later
• MPE720: Version 5.21 or later
• MPE720 Version 6: All versions

( 3 ) Setting Procedure for Clearing D Registers at Startup

Use the following procedure to make the setting.

1.

Connect the MPE720 online.

Select File (F) - Environment Setting - Setup.

2.

Select Enable under the D Register Clear when Start.

3.

Save data to flash memory before turning OFF the power supply.

The system will start with the D registers cleared to zeroes the next time that the flash memory starts.

( 4 ) Application Precautions

• Due to the nature of this function, it will only be enabled when starting with flash memory after having set this

function to “enabled” and saving to flash memory.

• It is not possible to clear the D registers for only a specific user program.
• No check is performed to see if the CPU Module supports the function to clear D registers at startup when the

MPE720 is offline. Therefore, confirm that the CPU Module that is being used supports the function to clear D
registers at startup before using this function.