2.

The following figure shows an example of the SERVOPACK Tab in the SVB Definition Window. The
values in Current Value are different from the values in Input Data.

( 4 ) SERVOPACK Parameters Saved in the MPE720

The data flow for SERVOPACK parameters is as follows when File - Save is selected from the SERVOPACK Tab
Page:

1.

The MPE720 writes all the parameters in Input Data currently displayed on SERVOPACK Tab Page of
the relevant axis to the followings.

• HDD (hard disk) of the personal computer
• SDRAM of MP2300S
• RAM and EEPROM of the SERVOPACK

2.

After having completed writing the parameters, the MPE720 updates the values in Current Value on
the SERVOPACK Tab Page with the SERVOPACK parameter values stored in the RAM.