A-78, 2 ) process result (param00) – Yaskawa MP2300S Basic Module User Manual

Page 400

Advertising
background image

Appendix G MSG-SND/MSG-RCV Functions (Ethernet)

G.1 Message Transmit Function (MSG-SND)

A-78

( 2 ) Process Result (PARAM00)

The process result is output to the upper byte. The lower byte is used for system analysis.

When an error occurs, take corrective action by referring to the following error contents:

Value of Process

Result

Meaning

00††H

In process (Busy)

10††H

Process completed (Complete)

8y††H

Error occurred (Error)

Value of Process

Result

Error Contents

Description

80††H

Reserved

81††H

82††H

Error in setting address

The following setting is out of range. Check the setting.
PARAM05 (data address)
PARAM11 (register offset)

83††H

Data size error

The transmit or receive data amount is out of range.
Check PARAM06 (data size).

84††H

Error in setting circuit number

The circuit number is out of range.
Check Cir-No (circuit number) of the MSG-SND function.

85††H

Error in setting channel number

The communication buffer channel number is out of range.
Check Ch-No (communication buffer channel number) of the MSG-
SND function.

86††H

Connection number error

The connection number is out of range.
Check PARAM02 (connection number).

87††H

Reserved

88††H

Communication section error

An error response was returned from the communication section (com-
munication device). Check the equipment connection. In addition, con-
firm that the remote device is open to communication.

89††H

Device select error

Unavailable device is set. Check Dev-Typ (communication device
type) of the MSG-SND function.

Advertising