6.2 Communication with Other MP Series

6.2.3 When the MP2300S Acts as Master (I/O message communication function is used)

6-43

Built-in Ethernet Communications

4.

Create a ladder program with a message receive function (MSG-RCV) in it.

An example of a ladder program for receiving messages in the remote equipment (MP2300) side follows:

„

Message receive function (MSG-RCV)

Required for receiving messages. Message reception is carried out by inputting and executing this message
receive function in a ladder program.

In addition, in order to support Read and Write by MP2300S, two message receive functions should be provided.
Here, the input item and parameters (Communication buffer channel number and Connection number) of the
message receive function need to accord with the MP2300S side settings.

Note: Similarly, a message receive function with the communication buffer channel number = 6 is required.

Fig. 6.7 MPE720 Module Configuration Definition Window

MSG  RCV

&$

&$







&#



&$

&$

&$

Communication device = Ethernet(218IF)

Protocol type

Circuit number = 1

Communication buffer channel number

Parameter list start address

=DA00000

Execute

Abort

Dev-Typ

Pro-Typ

Cir-No
Ch-No

Param

Busy

Complete

Error

Communication device = 218IF

Circuit number = 1