Jconnections to the sgdb- jj an servopack – Yaskawa MP930 User Manual

Page 125

Advertising
background image

4.2 Connection Methods

4 -23

J

Connections to the SGDB-jjAN Servopack

CN1

P1

B

N

Forward drive prohibited

Servopack
SGDB-jjAN

Connector shell

+24 V

+24 V

3.3 KΩ

Forward drive prohibit limit switch

Reverse drive prohibit limit switch

Zero point return deceleration limit

switch

Current position external latch/zero

N−LS

P−OT

6

7

N−OT

P−LS

DEC−LS

/DEC

/EXT

LATCH−LS

Reverse drive prohibited

Zero point return

deceleration limit

Current position latch

signals

For absolute encoder

Backup battery *4
(To battery module)

BAT(−)

BAT(+)

15

14

BRK

+24 V

0 V

CN2

PG

W

V

U

Be sure to connect the

shield wire at the end Unit.

Optical
encoder

BR

Brake

BR

K

100 VAC
200 VAC

P

8

9

10

1

2

3

4

BRK

SG−BRK

ALM

SG−ALM

BAT

0⋅BAT

R1

T1

MECHATROLINK 1

MECHATROLINK 2

T

r

t

R

S

S1

r
t

Do not connect.

For regenerative resistance connection

*1

Brake control output

Alarm output

*2

Brake control relay

Photocoupler output
Maximum operational voltage: 30 VDC
Maximum output current: 50 mA DC

CN3

1

2
3

4

5

6
7

8

*3

* 1. There is no P1 terminal for a Servopack with a

capacity of less than 5 kW.

* 2. Fordetails on MECHATROLINKconnections,

see 4.2.4.

* 3. When a brake built into the motor or an exter-

nal brake is used, a BRK signal is received by
the relay and controls the brake.

* 4. Connectedwhenanabsoluteencoderisused.
* 5. For Zero point return methods 1 and 2, con-

nect ZERO signal (Zero point LS) to /EXT sig-
nal.

Brake

power

supply

M

Motor

The shielded wire is connected

to the connector shell.

*5

4