C.3 monitor parameter list – Yaskawa MP930 User Manual

Page 323

Advertising
background image

C.3 Monitor Parameter List

C -5

C.3 Monitor Parameter List

The following table shows a list of the monitor parameters.

No.

Name

Register

Number

Setting Range

Meaning

Initial Value

1

Operation status

IWxx00

Each bit

2

MECHATROLINK servo status

IWxx01

Each bit

3

Machine coordinate system calcula-
tion position monitor

ILxx02

−2

31

to 2

31

−1

1 = 1 reference unit

CPOS

4

Target position incremental mode

ILxx04

0 to ±2

16

1 = 1 reference unit

5

Machine coordinate system latch
position monitor

ILxx06

−2

31

to 2

31

−1

1 = 1 reference unit

LPOS

6

Machine coordinate system feedback
position monitor

ILxx08

−2

31

to 2

31

−1

1 = 1 reference unit

APOS

7 to 10 Not used

IWxx0A to
IWxx0E

11

Range exceeded parameter No.

IWxx0F

1 to 47
101 to 127

12

13

Not used

IWxx10 to
IWxx13

14

Motion command response code

IWxx14

0 to 65535

Motion command currently be-
ing executed

15

Motion command status

IWxx15

Each bit

16

Number of digits after the decimal
point

IWxx16

0 to 5

Same as fixed parameter 18
(“number of digits after decimal
point”)

17

Position control status

IWxx17

18

Machine coordinate system reference
position

ILxx18

−2

31

to 2

31

−1

1 = 1 reference unit

MPOS

19

Not used

ILxx1A

20

POSMAX monitor

ILxx1C

1 to 2

31

−1

1 = 1 reference unit

21

Number of POSMAX turns

ILxx1E

−2

31

to 2

31

−1

1 = 1 rotation

22

Servo driver user monitor informa-
tion

ILxx20

−2

31

to 2

31

−1

23

Alarm

ILxx22

Each bit

Servo-related alarm

24

Servo driver ALARM code

IWxx24

Servopack alarm code

25

Servo driver I/O monitor

IWxx25

Each bit

26

Speed reference output value monitor ILxx26

−2

31

to 2

31

−1

1 = 1 reference unit/sec

C

Advertising