Parameters

5.2.1 Fixed Parameters

5 -18

Parameter

No.

Default

Description

Name

17

Servo control-
ler function
selection flags

b0 to b3

0 to 7:

Reference unit selection range

Sets reference unit for positioning control.
0: pulse (Electronic gear disabled)
1: mm
2: deg
3: inch

1

b4:

Electronic gear

Enables or disables the electronic gear in the servo controller. Use in com-
bination with Reference Unit Selection.

0: Disabled
1: Enabled

Note: The electronic gear will be disabled even if this flag is enabled if

Reference Unit Selection = pulse.

0

b5:

Finite length/infinite length axis selection
Determines whether or not there is a limit on controlled axis movement.

0

b5

Meaning

Reference

Range

0

S

Sets finite length axis.

S

The axis will have limited movement.

S

The stored stroke limit function is enabled.

−21

31

to

2

31

−1

1

S

Sets infinite length axis.

S

The axis will have unlimited movement.

S

The stored stroke limit function is disabled.

b6:

Not used.

0

b7:

Positive stored stroke limit function selection
Enables or disables the stored stroke limit function in the positive direction.

0: Disabled, 1: Enabled

0

b8:

Negative stored stroke limit function selection
Enables or disables the stored stroke limit function in the negative direc-
tion.

0: Disabled, 1: Enabled

0

b9:

Override function selection
Enables or disables the speed override function.

0: Disabled, 1: Enabled

The OWxx2C: Override setting is enabled if this parameter is enabled.
Override is fixed at 100% if this parameter is disabled.

0

b10 to b15: Not used.

0

5