Yaskawa MP930 User Manual

Page 190

Advertising
background image

5.1 Description of Parameters

5 -5

No.

Default

Meaning

Setting Range

Register

No.

Name

41

Positioning completed check time OWxx34

0 to 65535

1 = 1 ms

0

42

MECHATROLINK servo user
constant No

OWxx35

b0 to b11: 1 to 4095

User constant Cn

0

constant No.

b12 to b15: 1 to 2

Number of words

0

43

MECHATROLINK servo user
constant

OLxx36

−2

31

to 2

31

−1

0

44

Encoder position at power OFF
(Low)

OLxx38

−2

63

to 2

63

−1

1 = 1 pulse

0

45

Encoder position at power OFF
(High)

OLxx3A

46

Absolute pulse position at power
OFF (Low)

OLxx3C

−2

63

to 2

63

−1

1 = 1 pulse

0

47

Absolute pulse position at power
OFF (High)

OLxx3E

Register Numbers
The address underlined in OWxx00 for each axis is the register number OWC000 in the Parameter Table with
the following offset added.
Offset for each axis = (Axis No. − 1) × 40H (64 words)
Leading address of setting parameters for each axis = Offset for each axis + OWC000
The following table lists the servo setting parameter register numbers for each axis.

Axis No.

OW Address

Axis No.

OW Address

1

OWC000 to OWC03F

8

OWC1C0 to OWC1FF

2

OWC040 to OWC07F

9

OWC200 to OWC23F

3

OWC080 to OWC0BF

10

OWC240 to OWC27F

4

OWC0C0 to OWC0FF

11

OWC280 to OWC2BF

5

OWC100 to OWC13F

12

OWC2C0 to OWC2FF

6

OWC140 to OWC17F

13

OWC300 to OWC33F

7

OWC180 to OWC1BF

14

OWC340 to OWC37F

5