Parameters

5.2.3 Monitor Parameters

5 -30

5.2.3 Monitor Parameters

The following table describes the servo monitor data reported by the servo controller. Be sure
to look through these because they are basic parameters.

These monitor parameters can be used as reference from ladder logic and motion programs.

The following table describes the monitor parameters.

No.

Name

Register

No.

Description

Remarks

1

Operating status

IWxx00

Monitors servo controller operating status.

b1: PRMERR

Setting parameter setting error

b2: FPRMERR

Fixed parameter setting error

b3 to b6

Not used.

b7: SVCRDY

Servo controller operation preparations
complete

b8: SVCRUN

Servo controller is running

b9

Not used.

b10

Not used.

b11

Not used.

b12

Not used.

b13: POSCOMP

Positioning complete signal

b14

Not used.

b15

Not used.

2

MECHATROLINK servo
status

IWxx01

b0:ALARM

Turns ON when an alarm is detected on the
Servopack. Reset the alarm by executing
the alarm reset (OWxx00 b6).

b1: WARNG

Turns ON when a warning is detected on
the Servopack. Reset the alarm by execut-
ing the alarm reset (OWxx00 b6).

b2: CMDRDY

Turns ON when the MECHATROLINK is
ready to receive the command.

b3: SVON

Turns ON when the servo turns ON.

b4: PON

Turns ON when the main power supply is
ON.

b5: MLOCK

Turns ON in machine lock status. Set the
machine lock by setting the OWxx2D b0.