9.2.4 System Register Configuration

9 -10

9.2.4 System Register Configuration

J

System Status

System status indicates the operating status and error details for the system. System status de-
tails are used to determine whether hardware or software is the cause of an error.

Table 9.1 System Status List

Name

Register No.

Contents

Reserved for
the System

SW00030 to
SW00039

(Not used)

CPU Status

SW00040

SB000400

READY

1: Normal, 0: Communications/Self-diagno-
sis error

SB000401

RUN

1: Running, 0: Stopped

SB000402

ALARM

1: Alarm, 0: Normal

SB000403

ERROR

1: Error, 0: Normal

SB000404

RESUME

1: Continued startup operation
0: New startup operation

SB000405

START STATUS

1: Restoration from power interruption
0: Ordinary restoration

SB000406

Reserved by system.

(Not used)

SB000407

WEN

1: WRITE enabled, 0: WRITE disabled

SB000408

Reserved by system.

(Not used)

SB000409

SB00040A

SB00040B

SB00040C

SB00040D

SB00040E

OPERATION STOP RE-
QUEST

1: STOP selection, 0: RUN selection

SB00040F

Reserved by system.

(Not used)

9