Monitor Parameter Alarm List

D -4

D.2 Setting Errors in Fixed and Setting Parameters

The following table shows the parameter No.1 operation status (bit 1 and bit 2).

Register Number

Bit

Alarm Name

Cause

Action

IWxx00

b1: PRMERR

Setting parameter
setting error

A setting that exceeds the setting
range has been made in a setting pa-
rameter.

Reset the setting parameter.

b2: FPRMERR Fixed parameter

setting error

A setting that exceeds the setting
range has been made in a fixed pa-
rameter.

Reset the fixed parameter.

The parameter number in which the setting range error has occurred can be identified using IWxx0
(Range Exceeded Parameter No.).

Parameter Number

Name

Register Number

Description

Remarks

11

Range exceeded pa-
rameter No.

IWxx0

S

When a setting that exceeds the setting
range has been made in a fixed parame-
ter or a setting parameter, the last pa-
rameter number in which a setting
range error occurred is stored.

S

Setting parameters: 1 to 47

S

Fixed parameters: 101 to 127