2 setting related parameters, Encoder selection setting – Yaskawa MP930 User Manual

Page 237

Advertising
background image

Absolute Position Detection

7.2.2 Setting Related Parameters

7 -6

7.2.2 Setting Related Parameters

This section describes absolute position detection parameters in the MP930 parameters.

Set the following parameters prior to starting up the absolute position detection system.

Table 7.1 MP930 Unit Parameters

Parameter No.

Name

Setting Range

Units

Initial
Value

Fixed
Parameter 3

Encoder selection

0: Incremental encoder

1: Absolute encoder

0

Fixed
Parameter 8

Number of FB pulses per
Servomotor 1 rotation

Multiples of 4 in a range
from 4 to 65535

1 = 1 pulse

2048

Fixed
Parameter 17
b5

Finite Length
Mode/Infinite Length
Mode Axis Selection

0: Finite Length Mode

Axis Setting

1: Infinite Length Mode

Axis Setting

0

Fixed
Parameter 22

Maximum Infinite Length
Counter value

1 to 2

31

−1

1 = 1
reference unit

360000

Fixed
Parameter 23

Maximum Absolute
Encoder Rotations

1 to ±2

31

−1

1 = 1 rotation 99999

Setting
Parameter 7
(OLxx06)

Zero Point Position Offset
Setting for a Machine
Coordinate System

0 to ±2

31

−1

reference
units

0

Table 7.2 Servopack User Constants

User Constant

Name

Setting Range

Units

Initial
Value

Cn-0001bE

Encoder selection

0: Incremental encoder

1: Absolute encoder

0

Cn-0032

Absolute Encoder Zero
Point Position Offset

0 to ±2

31

−1

reference
units

0

Encoder Selection Setting

MP930 fixed parameter 3 and Servopack user constant Cn-0001bE are used to set absolute en-
coder for the axis whose absolute position will be detected.

Absolute position detection system can be set for each axis and any combination of incremental
and absolute position detection is possible in this system.

7