MP930 Specifications and System Configuration
2.2.4 Programming Device
2 -34
2.2.4 Programming Device
Using the CP-717 Windows 95-compatible programming software increases the ease of pro-
gramming, design efficiency, and the testing efficiency.
The CP-717 is provided with special functions, as support tools for the design, testing, and
maintenance of the sequence and motion programs.
Standard computer
POWER
RDY
ERR
PRT1
BAT
RUN
ALM
PRT2
SW1
CP-717
MP930
Figure 2.2
Programming Device
Basic Functions
The CP-717 has the five main functional areas, as shown in the following table.
Name
Functions
File Manager
Control functions for file management and online/offline control,
logoff, CPU control, etc.
Definitions
Functions for defining system definitions, such as the Unit configu-
ration
Programming
Programming functions for sequence programs (ladder logic pro-
grams) and motion programs
Debugging and Monitoring Functions for program maintenance management: Register lists,
adjustment panels, program monitoring, position monitoring, task
monitoring, etc.
Printing
Printing functions for definitions, programming, debugging, moni-
toring, etc.
2