Jsystem i/o error status – Yaskawa MP930 User Manual
Page 279
Advertising
Troubleshooting
9.2.4 System Register Configuration
9 -20
J
System I/O Error Status
Name
Register No.
Remarks
I/O Error Count
SW00200
Number of I/O errors
Number Of Input Errors
SW00201
Number of input errors
Input Error Address
SW00202
Latest input error address (For future use)
(Register number of OWxxx)
Output Error Count
SW00203
Number of times an output error has occurred
Output Error Address
SW00204
Latest input error address (For future use)
(Register number of OWxxx)
Reserved by system.
SW00205
(Not used)
SW00206
SW00207
I/O error status
SW00208 to
SW00211
(Not used)
SW00212 to
SW00215
(Not used)
SW00216
Slot = NET
D15
D0
. . . . . . . . . . . . . . . . . . . . .
0: OK
1: NG
ST#1
ST#2
I/O only
9