Yaskawa MP930 User Manual

Page 79

Advertising
background image

Basic System Operation

3.4.3 Motion Programming

3 -20

Table 3.7 shows an example of the default external input signals that are allocated by the
MP930 on the Group Definition Screen.

Table 3.7 External Input Signals and Motion Program Control Signals

External Signal

Address

External Signal Name

BIT

Motion Program Control

Signal

IB00000:

Program operation start

B0:

Program operation start request

IB00001:

Program pause

B1:

Program pause request

IB00002:

Program stop

B2:

Program stop request

IB00003:

Program debugging mode

B3:

Program debugging mode selection

IB00004:

Program debugging start

B4:

Program debugging start request

IB00005:

Alarm reset

B5:

Alarm reset request

J

Automatic Generation of Ladder Logic Programs for Motion
Program Control

An automatic generation function for the ladder logic programs used to control motion pro-
grams is provided with the MP930. This function enables JOG operations and program opera-
tions to be performed without the need for special ladder logic programs to be created, and
greatly reduces the system startup time.

3

A

EXAMPLE

"

Advertising