Efficient Networks Siemens Sinamics S120 User Manual

Page 101

Advertising
background image

Servo control

3.13 Pole position identification

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

101

Determining a suitable technique for the pole position identification routine

&DQWKHPRWRUURWDWHIUHHO\ QR

H[WHUQDOIRUFHV "

<HV

<HV

1R

1R

,VWKHPRWRULURQOHVV"

$VDWXUDWLRQEDVHGPHWKRGFDQEH

XVHG

6HWPHWKRG 
(QDEOHSXOVHVDQGVWDUWSROH
SRVLWLRQLGHQWLILFDWLRQ

3ROHSRVLWLRQLGHQWLILFDWLRQQRW
SRVVLEOH

$PHFKDQLFDOO\DGMXVWHG
HQFRGHUZLWKDEVROXWHLQIRUPDWLRQ
PXVWEHXVHG

Figure 3-20 Selecting the appropriate technique

Overview of key parameters

● p0325[0...n] Motor pole position identification current 1st phase
● p0329[0...n] Motor pole position identification current
● p0404.15 Commutation with zero mark
● p0431 Angular commutation offset
● p1980[0...n] Pole position identification procedure
● p1981[0...n] Pole position identification maximum movement
● p1982[0...n] Pole position identification selection
● p1983 Pole position identification test
● r1984 Pole position identification angular difference
● r1985 Pole position identification saturation curve
● r1987 Pole position identification trigger curve
● p1990 Pole position identification commutation angle offset commissioning
● r1992 Pole position identification diagnostics
● p1993 Pole position identification current, motion based
● p1994 Pole position identification rise time motion based
● p1995 Pole position identification motion based P gain
● p1996 Pole position identification motion based integral action time
● p1997 Pole position identification motion based smoothing time