Basic information about the drive system

12.13 Licensing

Drive Functions

532

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Information regarding the Performance 1 option (this is not valid for Control Unit CU310)

The option Performance 1 (Order No.: 6SL3074-0AA01-0AA0) is required from a

computation time utilization greater than 50%. The remaining computation time is displayed

in parameter r9976[2]. As of a CPU runtime utilization greater than 50%, alarm A13000 is

output and the READY LED on the Control Unit flashes green/red at 0.5 Hz.

Properties of the license key

● Assigned to a specific CompactFlash card.
● Is stored on the non-volatile CompactFlash card.
● Is not transferable.
● Can be acquired using the "WEB License Manager" from a license database.

Generating a license key via the "WEB License Manager"

The following information is required:
● Serial number of the CompactFlash card (on CF card)
● License number, delivery note number, and the license (on the Certificate of License)
1. Call up the "WEB License Manager".

http://www.siemens.com/automation/license

2. Choose "Direct access".
3. Enter the license number and delivery note number of the license.

--> Click "Next".

4. Enter the serial number of the CompactFlash card.
5. Select the product e.g. "SINAMICS S CU320".

--> Click "Next".

6. Choose "Available license numbers".

--> Click "Next".

7. Check the assignment.

--> Click "Assign".

8. When you are sure that the license has been correctly assigned, click "OK".
9. The license key is displayed and can be entered.

Entering the license key

Example of a license key:
E1MQ-4BEA = 69 49 77 81 45 52 66 69 65 dec (ASCII characters)
Procedure for entering a license key (see example):
1. p9920[0] = 69 1st character

...

Advertising