Vector V/f control (r0108.2 = 0)

5.4 Vdc control

Drive Functions

178

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Function diagrams (see SINAMICS S List Manual)

● 6320 Vdc_max controller and Vdc_min controller

Overview of key parameters (see SINAMICS S List Manual)

● p1280[0...n] Vdc controller configuration (V/f)
● r1282 Vdc_max controller switch-in level (V/f)
● p1283[0...n] Vdc_max controller dynamic factor (V/f)
● p1285[0...n] Vdc_min controller switch-in level (kinetic buffering) (V/f)
● r1286 Vdc_min controller switch-in level (kinetic buffering) (V/f)
● p1287[0...n] Vdc_min controller dynamic factor (kinetic buffering) (V/f)
● p1290[0...n] Vdc controller proportional gain (V/f)
● p1291[0...n] Vdc controller integral action time (V/f)
● p1292[0...n] Vdc controller derivative action time (V/f)
● p1293 Vdc controller output limit (V/f)
● p1294 Vdc_max controller automatic detection ON signal level (V/f)
● p1295 Vdc_min controller time threshold (V/f)
● p1296[0...n] Vdc_min controller response (kinetic buffering) (V/f)
● p1297[0...n] Vdc_min controller speed threshold (V/f)
● r1298[0...n] CO: Vdc controller output (V/f)