Basic information about the drive system

12.6 Parameterizing using the BOP20 (Basic Operator Panel 20)

Drive Functions

494

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Parameter display

The parameters are selected in the BOP20 using the number. The parameter display is

reached from the operating display by pressing the "P" key. Parameters can be searched for

using the arrow keys. The parameter value is displayed by pressing the "P" key again. You

can toggle between the drive objects by simultaneously pressing the keys "FN" and the

arrow keys. You can toggle between r0000 and the parameter that was last displayed by

pressing the "FN" key in the parameter display.

RU



3DUDPHWHUGLVSOD\

9DOXHGLVSOD\

2SHUDWLQJGLVSOD\

3$GMXVWDEOHSDUDPHWHU

LQLQGH[HG

U9LVXDOL]DWLRQSDUDPHWHU

%LQHFWRUSDUDPHWHU
EL%LQHFWRULQSXW
ER%LQHFWRURXWSXW
FL&RQQHFWRULQSXW
FR&RQQHFWRURXWSXW

 <RXFDQWRJJOHEHWZHHQUDQGWKHSDUDPHWHUWKDWZDVODVWGLVSOD\HGE\SUHVVLQJWKH
)1NH\LQWKHSDUDPHWHUGLVSOD\

Figure 12-15 Parameter display