Communication PROFIBUS DP/PROFINET IO

10.1 Communications according to PROFIdrive

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

369

Bit

Meaning

Comments

BICO

4

DDS eff., bit 4

BO: r0051.4

5, 6 Reserved

1

Axis parking active

7

Parking axis

0

Axis parking not active

BO: r0896.0

1

Travel to fixed endstop

8

Travel to fixed endstop

0

No travel to fixed stop

BO: r1406.8

9, 10 Reserved

1

Data record changeover active

11 Data set changeover

0

No data set changeover active

BO: r0835.0

12 Drive unit sign-of-life bit 0

User data integrity (4-bit counter)

Implicitly

interconnected

13 Drive unit sign-of-life bit 1

14 Drive unit sign-of-life bit 2

15 Drive unit sign-of-life bit 3

NACT_A (Speed setpoint A (16 bit))

● Actual speed value with 16-bit resolution.
● The speed actual value is normalized in the same way as the setpoint (see NSOLL_A).

NACT_B (Speed setpoint B (32 bit))

● Actual speed value with 32-bit resolution.
● The speed actual value is normalized in the same way as the setpoint (see NSOLL_B).

Gn_ZSW (encoder n status word)

Gn_XIST1 (encoder n position actual value 1)

Gn_XIST2 (encoder n position actual value 2)

This process data belongs to the encoder interface.

ITIST_GLATT

The actual current value smoothed with p0045 is displayed.

MELDW (message word)

See function diagram [2456]

Table 10-14 Description of MELDW (message word)

Bit

Meaning

Comments

BICO

0

Ramp-up/ramp-down completed /

ramp-function generator active

1

Ramp-up/ramp-down completed.

The ramp-up procedure is completed once the

speed setpoint has been changed.