12.10 Rules for wiring with DRIVE-CLiQ

Drive Functions

510

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

12.10.2 Rules for different firmware releases

Rules for FW2.1

● Only one Active Line Module can be connected to a Control Unit.
● The default sampling times must not be changed.
● A Double Motor Module must not be operated as a single drive.
● Mixed operation of servo and vector V/f is not permitted.
● The Active Line Module and the Motor Modules must be connected to separate DRIVE-

CLiQ lines, both for vector and for servo.

Table 12-16 Maximum number of drives that can be controlled by a Control Unit 320

Servo

Vector

Number of components 1 Active Line Module +

6 Motor Modules

1 Active Line Module +

2 Motor Modules

(scanning frequency of current controller

250 µs /

speed controller 1000 µs)

Note:
In addition, the "Safe Standstill" function can be activated and a TM31 connected.

Rules for FW2.2

● Only one Active Line Module can be connected to a Control Unit.
● The default sampling times must not be changed.
● A Double Motor Module must not be operated as a single drive.

Table 12-17 Maximum number of drives that can be controlled by a Control Unit 320

Servo

Vector V/f (=vector

without speed control

function module)

Vector

1 Active Line Module +

6 Motor Modules

1 Active Line Module +

4 Motor Modules

(sampling time of current

controller 250 µs)
1 Active Line Module +

6 Motor Modules

(sampling time of current

controller 400 µs)

Number of

components

Servo and vector V/f:
1 Active Line Module + 5 Motor Modules

(servo: Current controller 125 µs / speed controller

125 µs vector V/f:
sampling time of current controller 250 µs with max.

2 V/f drives. Sampling time of current controller 400 µs

with more than 2 V/f drives)

1 Active Line Module +

2 Motor Modules

(sampling time of current

controller 250 µs / speed

controller 1000 µs)
1 Active Line Module +

4 Motor Modules

(sampling time of current

controller 400 µs / speed

controller 1600 µs)