background image

Extended setpoint channel

2.8 Suppression bandwidths and setpoint limits

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

59

6XSSUHVVLRQ

EDQGZLGWKV

6SHHGOLPLWLQJPD[

6SHHGOLPLWLQJPLQ

5DPSIXQFWLRQJHQHUDWRU

0RWRUFRQWURO

0LQ

0D[

U

S>'@



S>'@

S>'@

S'@

S>'@

U



\

[

S

S>&@

 

S>'@

\

\

U

U

S

S>&@

 

[

[

\

[



S>'@

Figure 2-7

Suppression bandwidths, setpoint limitation

Function diagrams (see SINAMICS S List Manual)

● 1550 Setpoint channel
● 3050 Suppression bandwidth and speed limiting

Overview of key parameters (see SINAMICS S List Manual)

Setpoint limitation

● p1080[D] Minimum speed
● p1082[D] Maximum speed
● p1083[D] CO: Speed limit in positive direction of rotation
● r1084 Speed limit positive effective
● p1085[C] CI: Speed limit in positive direction of rotation
● p1086[D] CO: Speed limit negative direction of rotation
● r1087 Speed limit negative effective