Communication PROFIBUS DP/PROFINET IO

10.1 Communications according to PROFIdrive

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

381

Bit Name

Signal status, description

0

No active parking encoder

1

Error from encoder or actual-value sensing is active.
Note:

The error code is stored in Gn_XACT2.

15 Encoder error

0

No error is active.

Encoder 1 actual position value 1 (G1_XACT1)

● Resolution: Encoder lines ∙ 2n

n: fine resolution, no. of bits for internal multiplication
The fine resolution is specified via p0418.

● Used to transmit the cyclic actual position value to the controller.
● The transmitted value is a relative, free-running actual value.
● Any overflows must be evaluated by the master controller.

)LQHLQIRUPDWLRQ

(QFRGHUOLQHV

,QWHUQDOPXOWLSOLFDWLRQ

)DFWRU\VHWWLQJ

SIRU*[B;,67 HQFRGHUWR





%LWb

Figure 10-14 Subdivision and settings for Gx_XIST1

● Encoder lines of incremental encoder

– For encoders with sin/cos 1Vpp:

Encoder lines = no. of sinusoidal signal periods

● After power-up: Gx_XIST1 = 0
● An overflow in Gx_XIST1 must be viewed by the master controller.
● There is no modulo interpretation of Gx_XIST1 in the drive.

Encoder 1 actual position value 2 (G1_XACT2)

Different values are entered in Gx_XACT2 depending on the function.
● Priorities for Gx_XIST2
The following priorities should be considered for values in Gx_XIST2: