background image

Basic information about the drive system

12.6 Parameterizing using the BOP20 (Basic Operator Panel 20)

Drive Functions

498

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Displaying alarms

$$ODUP

1HZDODUPVRUDODUPVSUHVHQW
DQGQRNH\SUHVVHGIRUDSSUR[
VHFRQGV

0RUHWKDQRQHDODUP
IURPWKHDFWLYHGULYH
DQGDQRWKHUGULYH

$ODUPVDUHFORFNHGWKURXJKDXWRPDWL
FDOO\

DIWHUVHFRQGV

DIWHUVHFRQGV

DIWHUVHFRQGV

Figure 12-20 Alarms

12.6.4

Controlling the drive using the BOP20

Description

When commissioning the drive, it can be controlled via the BOP20. A control word is

available on the Control Unit drive object (r0019) that can be interconnected with the

appropriate binector inputs e.g. of the drive or the infeed.
The interconnections do not function if a standard PROFIdrive telegram was selected as its

interconnection cannot be disconnected.

Table 12-10 BOP20 control word

Bit (r0019)

Name

Example, interconnection parameters

0

ON / OFF (OFF1)

p0840

1

No coast down/coast down (OFF2)

p0844

2

No fast stop/fast stop (OFF3)

p0848

Note:

For simple commissioning, only bit 0 should be interconnected. When interconnecting bits 0 ... 2,

then the system is powered-down according to the following priority: OFF2, OFF3, OFF1.
7

Acknowledge fault (0 -> 1)

p2102

13

Motorized potentiometer, raise

p1035

14

Motorized potentiometer, lower

p1036