Function modules

7.8 Closed-loop position control

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

237

kT estimator:

● p1752 Motor model, changeover speed operation with encoder
● p1795 Motor model PEM k

T

adaptation smoothing time

● r1797 Motor model PEM k

T

adaptation correction value

Compensation of the voltage emulation error of the drive converter:

● p1952 Voltage emulation error, final value
● p1953 Voltage emulation error, current offset

7.8

Closed-loop position control

7.8.1

General features

The position controller essentially comprises the following parts:
● Position actual value conditioning (including the lower-level measuring probe evaluation

and reference mark search)

● Position controller (including limits, adaptation and the pre-control calculation)
● Monitoring functions (including standstill, positioning, dynamic following error monitoring

and cam signals)

● There is still no position actual value conditioning for distance-coded measuring systems.
● Position tracking of the load gear (motor encoder), using absolute encoders for rotary

axes (modulo) as for linear axes.

7.8.2

Position actual value conditioning

7.8.2.1

Features

● Correction value (p2512, p2513)
● Setting value (p2514, p2515)
● Position offset (p2516)
● Position actual value (r2521)
● Velocity actual value (r2522)
● Motor revolutions (p2504)
● Load revolutions (p2505)
● Spindle pitch (p2506)
● Position tracking (p2720ff)