Basic information about the drive system

12.11 Notes on the number of controllable drives

Drive Functions

522

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Servo control

● Servo without extra function modules (e.g. setpoint channel):

PROFIBUS-DP cycle >=1 ms
– 6 drives (sampling times: current controller 125 µs / speed controller 125 µs), of which

max. 2 induction motors or

2 drives (sampling times: current controller 62.5 µs / speed controller 62.5 µs), both

also induction motors

– 6 motor measuring systems
– 3 direct measuring systems
– 1 Terminal Module TM31 or 1 Terminal Board TB30 with 1 ms sampling time
– 1 Active Line Module with 250 µs sampling time without Voltage Sensing Module

● Servo without extra function modules (e.g. setpoint channel):

PROFIBUS-DP cycle >= 500 µs and < 1 ms, valid for integrated SINAMICS drives for

SIMOTION and SINUMERIK
– 5 drives (sampling times: current controller 125 µs / speed controller 125 µs), of which

max. 2 induction motors or

2 drives (sampling times: current controller 62.5 µs / speed controller 62.5 µs), both

also induction motors

– Remaining modules as above

● Servo with CBE20 function module:

PROFINET-IO bus cycle time > = 1 ms
– 5 drives (sampling times: current controller 125 µs / speed controller 125 µs), of which

max. 2 induction motors or

1 drive (sampling times: current controller 62.5 µs / speed controller 62.5 µs),

induction motor also possible

– 5 motor measuring systems
– 2 direct measuring systems
– 1 Terminal Module TM31 or 1 Terminal Board TB30 with 1 ms sampling time
– 1 Active Line Module with 250 µs sampling time without Voltage Sensing Module

● Servo with CBE20 function module:

PROFINET-IO bus cycle time > = 500 µs and < 1 ms
– 4 drives (sampling times: current controller 125 µs / speed controller 125 µs), of which

max. 2 induction motors or

1 drive (sampling times: current controller 62.5 µs / speed controller 62.5 µs),

induction motor also possible

– Remaining modules as above

● Servo with EPOS function module

– 3 drives (sampling times: current controller 125 µs / speed controller 125 µs / position

controller 1 ms / positioning 4 ms)

– 3 motor measuring systems
– 1 Active Line Module with 250 µs sampling time without Voltage Sensing Module