7.9 Basic positioner

Drive Functions

278

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

● xx2x = ABS_POS -> p2648, p2651
● xx3x = ABS_NEG -> p2648, p2652

Intermediate stop and canceling traversing block

The intermediate stop is activated by a 0 signal at p2640. After activation, the system brakes

with the parameterized deceleration value (p2620 or p2645).
The current traversing task can be canceled by a 0 signal at p2641. After activation, the

system brakes with the maximum deceleration (p2573).
The "intermediate stop" and "cancel traversing task" functions are only effective in the

modes "traversing blocks" and "direct setpoint input/MDI".

Function diagrams (see SINAMICS S List Manual)

● 3618 EPOS - direct setpoint input mode/MDI, dynamic values
● 3620 EPOS - direct setpoint input mode/MDI

Overview of key parameters (see SINAMICS S List Manual)

● p2577 BI: EPOS modulo offset activation
● p2642 CI: EPOS direct setpoint input/MDI, position setpoint
● p2643 CI: EPOS direct setpoint input/MDI, velocity setpoint
● p2644 CI: EPOS direct setpoint input/MDI, acceleration override
● p2645 CI: EPOS direct setpoint input/MDI, delay override
● p2648 BI: EPOS direct setpoint input/MDI, positioning type
● p2649 BI: EPOS direct setpoint input/MDI, acceptance type
● p2650 BI: EPOS direct setpoint input/MDI, setpoint acceptance edge
● p2651 BI: EPOS direct setpoint input/MDI, positive direction selection
● p2652 BI: EPOS direct setpoint input/MDI, negative direction selection
● p2653 BI: EPOS direct setpoint input/MDI, setup selection
● p2654 CI: EPOS direct setpoint input/MDI, mode adaptation
● p2690 CO: EPOS position, fixed setpoint
● p2691 CO: EPOS velocity, fixed setpoint
● p2692 CO: EPOS acceleration override, fixed setpoint
● p2693 CO: EPOS delay override, fixed setpoint

Advertising