2 dds: drive data set – Efficient Networks Siemens Sinamics S120 User Manual

Page 471

Advertising
background image

Basic information about the drive system

12.2 Data sets

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

471

Example: Switching between command data set 0 and 1

&'6VHOHFWHG

&'6HIIHFWLYH

&KDQJHRYHUWLPH





















W





W

S  

S  

S  

S  

U 

U 

U 

U 

&'6

Figure 12-3 Switching the command data set (example)

12.2.2

DDS: Drive Data Set

DDS: Drive Data Set

A drive data set contains various adjustable parameters that are relevant with respect to

open and closed-loop drive control:
● Numbers of the assigned motor and encoder data sets:

– p0186: assigned motor data set (MDS)
– p0187 to p0189: up to 3 assigned encoder data sets (EDS)

● Various control parameters, e.g.:

– Fixed speed setpoints (p1001 to p1015)
– Speed limits min./max. (p1080, p1082)
– Characteristic data of ramp-function generator (p1120 ff)
– Characteristic data of controller (p1240 ff)
– ...

The parameters that are grouped together in the drive data set are identified in the

SINAMICS S List Manual by "Data Set DDS" and are assigned an index [0..n].
More than one drive data set can be parameterized. You can switch easily between different

drive configurations (control type, motor, encoder) by selecting the corresponding drive data

set.
One drive object can manage up to 32 drive data sets. The number of drive data sets is

configured with p0180.

Advertising