Extended setpoint channel

2.7 Direction of rotation limiting and direction of rotation changeover

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

57

Display parameters

r1073[C] CO: Main setpoint effective
r1077[C] CO: Supplementary setpoint effective
r1078[C] CO: Total setpoint effective

Parameterization with STARTER

The "Speed setpoint" parameter screen is selected with the

icon in the toolbar of the

STARTER commissioning tool:

2.7

Direction of rotation limiting and direction of rotation changeover

Description

A reverse operation involves a direction reversal. A direction reversal in the setpoint channel

can be triggered by selecting direction reversal p1113[CDS].
If, on the other hand, a negative or positive setpoint is not to be preselected via the setpoint

channel, this can be prevented via parameter p1110[CDS or p1111[CDS]. However, the

following settings for minimum speed (p1080) in the setpoint channel are still operative. With

the minimum speed, the motor can turn in a negative direction, although p1110 = 1 is set.

6XSSUHVVLRQEDQGZLGWKV

VHWSRLQWOLPLWDWLRQV

 ,QKLELWSRVLWLYHGLUHFWLRQ

 ,QKLELWQHJDWLYHGLUHFWLRQ

 'LUHFWLRQRIURWDWLRQUHYHUVDO

5DPSIXQFWLRQJHQHUDWRU

0RWRUFRQWURO

S>&@

S>&@

S>&@















Figure 2-6

Direction of rotation limiting and direction of rotation changeover