Communication PROFIBUS DP/PROFINET IO

10.3 Communications via PROFINET IO

Drive Functions

446

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Refresh time

The refresh time is in the range of 1 ms, 2 ms and 4 ms. The real refresh time depends on

the bus load, the devices used and the quality structure of the I/O data. The refresh time is a

multiple of the send clock.

10.3.3.3 PROFINET IO with IRT - Overview

Overview

PROFINET IO with IRT distinguishes itself through the separate time domains for IRT, RT

and TCP/IP communication. This is ensured by high-precision hardware-supported cycle

monitoring.

,57SDUW

,57SDUW

,57SDUW

7&3,3

SDUW

7&3,3

SDUW

7&3,3

SDUW

6HQGFORFNLQWHUYDO

HJPVSRVLWLRQFRQWUROOHUFORFNF\FOH

,VRFKURQRXV

FRPPXQLFDWLRQ

7&3,3

FRPPXQLFDWLRQ

,2GDWD

7&3,3GDWD

6HQGFORFNLQWHUYDO

6HQGFORFNLQWHUYDO

Figure 10-47 IRT Communication - Overview

PROFINET IO with IRT is available in two versions:
● IRTflex (flexible) with fixed bandwidth reservation (not available in FW2.5 SP1)
● IRTtop (top performance) with planned IRT communication

Time synchronization and isochronous mode on PROFINET IO with IRTtop

In addition, a high-performance and isochronous connection to the application with low load

on the application CPU is also ensured. Isochronous data transfer with cycle times well

below one millisecond and with a deviation in the cycle start (jitter) of less than a

microsecond provide sufficient performance reserves for demanding motion control

applications.
In contrast to standard Ethernet and PROFINET IO with RT, the message frames for

PROFINET IO with IRT are transmitted as scheduled.

Sync domain

The sync domain can be configured in the HW Config. SINAMICS S120 is an IO device and

must be assigned to a sync master as a sync slave.