2 measuring gear, 1 features, 2 description – Efficient Networks Siemens Sinamics S120 User Manual

Page 208

Advertising
background image

Basic functions

6.14 Position tracking

Drive Functions

208

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

The encoder position actual value in r0483 (must be requested via GnSTW.13) is limited to

2

32

places. When position tracking (p0411.0 = 0) is switched off, the encoder position actual

value r0483 comprises the following position information:
● Encoder pulses per revolution (p0408)
● Fine resolution per revolution (p0419)
● Number of resolvable revolutions of the rotary absolute encoder (p0421), this value is

fixed at "1" for singleturn encoders.

When position tracking (p0411.0 = 1) is activated, the encoder position actual value r0483 is

composed as follows:
● Encoder pulses per revolution (p0408)
● Fine resolution per revolution (p0419)
● Virtual number of resolvable motor revolutions of a rotary absolute encoder (p0412)

If the measuring gear is absent (n=1), the actual number of the stored revolutions of a

rotary absolute encoder p0421 is used. The position area can be extended by increasing

this value.
If the measuring gear is available, this value equals the number of resolvable motor

revolutions, which is stored in r0483.

● The gear ratio (p0433/p0432)

6.14.2

Measuring gear

6.14.2.1 Features

Measuring gear characteristics

● Configuration via p0411
● Virtual multiturn via p0412
● Tolerance window for monitoring the position at switching on p0413
● Input of the measuring gear via p0432 and p0433
● Display via r0483

6.14.2.2 Description

If a mechanical gearbox (measuring gearbox) is located between an endlessly rotating

motor/load and the encoder and position control is to be carried out using this absolute

encoder, an offset occurs (depending on the gearbox ratio) between the zero position of the

encoder and the motor/load whenever encoder overflow occurs.

Advertising