Servo control

3.16 Travel to fixed stop

Drive Functions

112

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

The motor runs at the set torque until it reaches the stop and continues to work against

the stop until the torque limit has been reached, this status being indicated in status bit
r1407.7 "Torque limit reached".

Control and status messages

Table 3-16 Control: Travel to fixed stop

Signal name

Internal control word

STW n_ctrl

Binector input

PROFIdrive p0922 and/or

p2079

Activates travel to fixed stop 8

p1545 Activates travel to fixed stop STW2.8

Table 3-17 Status message: Travel to fixed stop

Signal name

Internal status word

Parameter

PROFIdrive p0922 and/or

p2079

Travel to fixed stop active

-

r1406.8

ZSW2.8

Torque limits reached

ZSW n_ctrl.7

r1407.7

ZSW1.11 (inverted)

Torque utilization < torque

threshold value 2

ZSW monitoring functions

3.11

r2199.11

MESSAGEW.1

Function diagrams (see SINAMICS S List Manual)

● 5610 Torque limiting/reduction/interpolator
● 5620 Motor/generator torque limit
● 5630 Upper/lower torque limit
● 8012 Torque messages, motor blocked/stalled

Overview of key parameters (see SINAMICS S List Manual)

● p1400[0...n] Speed control configuration
● r1407.7 BO: Torque limit reached
● p1520[0...n] CO: Torque limit, upper/motoring
● p1521[0...n] CO: Torque limit, lower/regenerative
● p1522[0...n] CI: Torque limit, upper/motoring
● p1523[0...n] CI: Torque limit, lower/regenerative
● r1526 Torque limit, upper/motoring without offset
● r1527 Torque limit, lower/regenerative without offset
● p1532[0...n] Torque limit offset
● p1542[0...n] CI: Travel to fixed stop, torque reduction
● r1543 CO: Travel to fixed stop, torque scaling
● p1544 Travel to fixed stop, evaluate torque reduction