Communication PROFIBUS DP/PROFINET IO

10.1 Communications according to PROFIdrive

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

355

Abbreviation

Name

Signal

number

Data type

1)

Interconnection

parameters

MDIAcc

Pos MDI acceleration override

225

I16

p2644

MDIDec

Pos MDI deceleration override

227

I16

p2645

MDIMode

Pos MDI mode

229

U16

p2654

E_STW1

Control word for INFEED

320

U16

(bit serial)

2)

CU_STW

Control word for Control Unit (CU)

500

U16

(bit serial)

1. 1) Data type according to PROFIdrive profile V4:

I16 = Integer16, I32 = Integer32, U16 = Unsigned16, U32 = Unsigned32

2. 2) Bit-serial interconnection: refer to the following pages

CTW1 (control word 1)

See function diagram [2442]

Table 10-4 Description of CTW1 (control word 1)

Bit

Meaning

Comments

BICO

0/1

ON

Pulse enable possible

0

ON/OFF1

0

OFF1

Braking with the ramp-function generator, then

pulse cancellation and power-on inhibit.

BI: p0840

1

No OFF2

Enable possible

OFF2

0

Immediate pulse cancellation and power-on

inhibit

BI: p0844

1

Note:

Control signal OFF2 is generated by ANDing BI: p0844 and BI: p0845.

1

No OFF3

Enable possible

OFF3

0

Emergency stop (OFF3)

Braking with OFF3 ramp p1135, then pulse

cancellation and power-on inhibit.

BI: p0848

2

Note:

Control signal OFF3 is generated by ANDing BI: p0848 and BI: p0849.

1

Enable operation

Pulse enable possible

3

Enable operation

0

Disable operation

Cancel pulses

BI: p0852

1

Operating condition

Ramp-function generator enable possible

4

Enable ramp-function generator

0

Inhibit ramp-function generator

Set ramp-function generator output to zero

BI: p1140

1

Start ramp-function generator

5

0

Freeze ramp-function generator

BI: p1141