Efficient Networks Siemens Sinamics S120 User Manual

Page 99

Advertising
background image

Servo control

3.13 Pole position identification

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

99

● Hall sensor
● Resolver with a multiple integer ratio between the motor pole pair number and the

encoder pole pair number

● Incremental encoder with a multiple integer ratio between the motor pole pair number and

the encoder pulse number

The pole position identification is used for:
● Determining the pole position (p1982 = 1)
● Determining the angular commutation offset during commissioning (p1990 = 1)
● Plausibility check for encoders with absolute information (p1982 = 2)

WARNING

When the motors are not braked, the motor rotates or moves as a result of the current

impressed during the measurement. The magnitude of the motion depends on the

magnitude of the current and the moment of inertia of the motor and load.

Notes regarding pole position identification

The relevant technique can be selected using parameter P1980. The following techniques

are available for a pole position identification routine:
● Saturation-based 1st+ 2nd harmonics (p1980 = 0)
● Saturation-based 1st harmonics (p1980 = 1)
● Saturation-based, two-stage (p1980 = 4)
● Saturation-based (p1980 = 10)
The following limitations/constraints apply for the saturation-based motion technique:
● This technique can be used for both braked and non-braked motors.
● It can only be used for a speed setpoint = 0 or from standstill.
● The specified current magnitudes (p0325, p0329) must be sufficient to provide a

significant measuring result.

● For motors without iron, the pole position cannot be identified using the saturation-based

technique.

● For 1FN3 motors, no traversing with the 2nd harmonic should take place (p1980 = 0,4).
● With 1FK7 motors, two-stage procedures must not be used (p1980 = 4). The value in

p0329, which is set automatically, must not be reduced.

For the motion-based technique, the following constraints apply:
● The motor must be free to move and it may not be subject to external forces (no

hanging/suspended axes)

● It can only be used for a speed setpoint = 0 or from standstill.
● If there is a motor brake, then this must be open (p1215 = 2).
● The specified current magnitude (p1993) must move the motor by a sufficient amount.

Advertising