Function modules

7.11 Parallel connection of chassis power units (vector)

Drive Functions

290

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Parallel connection of two Active Line Modules and two Motor Modules on a motor with a single

winding system





89:

$FWLYH/LQH0RGXOH

0RWRU0RGXOH

0RWRU0RGXOH

9ROWDJH

6HQVLQJ
0RGXOH

$FWLYH
,QWHUIDFH
0RGXOH

9ROWDJH

6HQVLQJ
0RGXOH

$FWLYH/LQH0RGXOH

&RQWURO8QLW

'5,9(

&/L4



$FWLYH
,QWHUIDFH
0RGXOH



0

Figure 7-26 Example 2: parallel connection

7.11.5

Commissioning

During commissioning, power units connected in parallel are treated like a power unit on the

line or motor side. With parallel connection, the parameter display for the actual values

changes only slightly. Instead, suitable "total values" are derived from the individual values

for the power units.
In STARTER, parallel connection (Line Modules and Motor Modules) is activated via the

Wizard. You can also select parallel connection when choosing the power unit. You then

have to specify the number of power units to be connected in parallel.

Advertising