Efficient Networks Siemens Sinamics S120 User Manual

Page 376

Advertising
background image

Communication PROFIBUS DP/PROFINET IO

10.1 Communications according to PROFIdrive

Drive Functions

376

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

Table 10-18 Description of the individual signals in Gn_STW

Bit

Name

Signal status, description

If bit 7 = 0, then find reference mark request applies:
Bit

Meaning

0

Function 1

Reference mark 1

1

Function 2

Reference mark 2

2

Function 3

Reference mark 3

3

Function 4

Reference mark 4

If bit 7 = 1, then find flying measurement request applies:
0

Function 1

Probe 1 rising edge

1

Function 2

Probe 2 falling edge

2

Function 3

Probe 3 rising edge

3

Function 4

Probe 4 falling edge

Note:

Bit x = 1

Bit x = 0

Request function

Do not request function

0
1
2
3

Find reference

mark or flying

measurement

Functions

The following applies if more than 1 function is activated:
The values for all functions cannot be read until each activated function

has terminated and this has been confirmed in the corresponding status

bit (STW.0/.1/.2/.3 "0" signal again).

Find reference mark
It is possible to search for a reference marker.

Equivalent zero mark

On-the-fly measurement
Positive and negative edge can be activated simultaneously.

Bit 6, 5, 4

Meaning

000

-

001

Activate function x

010

Read value x

011

Terminate function

4
5
6

Command

(x: function selected via bit 0-3)
1

Measurement on-the-fly (fine resolution via p0418)

7

Mode

0

Find reference marker (fine resolution via p0418)

0...

12

Reserved

-

1

Request cyclic transmission of the absolute position actual value in

Gn_XIST2.
Used for (e.g.):

Additional measuring system monitoring

Synchronization during ramp-up

13 Request cyclic absolute value

0

No request

1

Request parking encoder (handshake with Gn_ZSW bit 14)

14 Parking encoder

0

No request

15 Acknowledge encoder error

0/1

Request to reset encoder errors

Advertising