10 overview of parameters and function diagrams – Efficient Networks Siemens Sinamics S120 User Manual

Page 338

Advertising
background image

Safety Integrated basic functions

9.10 Overview of parameters and function diagrams

Drive Functions

338

Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

9.10

Overview of parameters and function diagrams

Parameter overview (see SINAMICS S List Manual)

Table 9-13 Parameters for Safety Integrated

No. of Control Unit

(CU)

No. of Motor

Module (MM)

Name

Changeable to

p9601

p9801

SI enable safety functions

p9602

p9802

SI enable safe brake control

p9620

-

SI signal source for Safe torque off

p9650

p9850

SI SGE changeover, tolerance time (Motor Module)

p9652

p9852

SI Safe Stop 1 delay time

p9658

p9858

SI transition time STOP F to STOP A

p9659

-

SI timer for the forced dormant error detection

Safety Integrated

commissioning

(p0010 = 95)

p9761

-

SI password input

In every operating mode

p9762

-

SI password new

p9763

-

SI password acknowledgment

Safety Integrated

commissioning

(p0010 = 95)

r9770[0...2]

r9870[0...2]

SI version safety function integrated in the drive

-

r9771

r9871

SI shared functions

-

r9772

r9872

SI CO/BO: Status

-

r9773

-

SI CO/BO: Status (Control Unit + Motor Module)

-

r9774

-

SI CO/BO: Status (Safe torque off group)

-

r9780

r9880

SI monitoring clock cycle

-

r9794

r9894

SI crosswise comparison list

-

r9795

r9895

SI diagnostics for STOP F

-

r9798

r9898

SI actual checksum SI parameters

-

p9799

p9899

SI target checksum SI parameters

Safety Integrated

commissioning

(p0010 = 95)

Description of the parameters

Note
The SINAMICS Safety Integrated parameters are described in the following documentation:
References: /LH1/ SINAMICS S List Manual - Section 1.2

Advertising