Communication PROFIBUS DP/PROFINET IO

10.1 Communications according to PROFIdrive

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

375

XistP

Actual position value is displayed
Normalization: 1 corresponds to 1 LU

10.1.3.5 Control and status words for encoder

Description

The process data for the encoders is available in various telegrams. For example, telegram 3

is provided for speed control with 1 position encoder and transmits the process data of

encoder 1.
The following process data is available for the encoders:
● Gn_CTW encoder n control (n = 1, 2, 3)
● Gn_ZSW encoder n status word
● Gn_XIST1 encoder n act. pos. value 1
● Gn_XIST2 encoder n act. pos. value 2

Note
Encoder 1: Motor encoder
Encoder 2: Direct measuring system
Encoder 3: Additional measuring system

Encoder 3 can be connected via p2079 and extension of the standard telegrams.

Example of encoder interface

6ODYH

0DVWHU

352),%86

*B67:
*B67:

*B=6:
*B=6:

*B;,67

*B;,67

*B;,67

*B67:
*B67:

*B=6:
*B=6:

*B;,67

*B;,67

*B;,67

Figure 10-11 Example of encoder interface (encoder-1: two actual values, encoder -2: an actual value)

Encoder n control word (Gn_CTW, n = 1, 2, 3)

The encoder control word controls the encoder functions.