4 analog outputs, Function diagrams (see sinamics s list manual), Properties – Efficient Networks Siemens Sinamics S120 User Manual

Page 489: Notice

Advertising
background image

Basic information about the drive system

12.5 Inputs/outputs

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

489

NOTICE

Parameters p4057 to p4060 of the scaling do not limit the voltage values/current values

(for TM31, the input can be used as current input).

Function diagrams (see SINAMICS S List Manual)

● 9104 Analog inputs (AI 0 and AI 1)
● 9566 Analog input 0 (AI 0)
● 9568 Analog input 1 (AI 1)
● 9663 Analog input (AI 0)

12.5.4

Analog outputs

6FDOLQJ

6PRRWKLQJ

S>@

2IIVHW

$GGLWLRQDO\IRU

FXUUHQWRXWSXW HJ

70

U>@

S>@ 

>@

U>@

S>@

S>@

[

\

[

\

[

\

S>@

S>@

ದ





S>@

S>@





S>@

>9@

>@







P$









S>@

$2

'

$

Figure 12-13 Analog outputs: Signal processing using AO 0 of TB30/TM31 as an example

Properties

● Adjustable absolute-value generation
● Inversion via binector input
● Adjustable smoothing
● Adjustable transfer characteristic
● Output signal can be displayed via visualization parameter

Advertising