Efficient Networks Siemens Sinamics S120 User Manual

Page 403

Advertising
background image

Communication PROFIBUS DP/PROFINET IO

10.1 Communications according to PROFIdrive

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

403

Parameter request

Offset

Subindex = 0 dec

26

Attribute = 10 hex

No. of elements = 01 hex

22 + 23

Parameter no. = 1059 dec

24

4. parameter address

Subindex = 0 dec

26

Attribute = 10 hex

No. of elements = 01 hex

22 + 23

Parameter no. = 1059 dec

24

4. parameter address

Subindex = 0 dec

26

Format = 07 hex

No. of values = 01 hex

28 + 29

Value = 02D2 hex

30

1. parameter value(s)

Value = 0404 hex

32

Format = 07 hex

No. of values = 01 hex

34 + 35

Value = 02D2 hex

36

2. parameter value(s)

Value = 0405 hex

38

Format = 08 hex

No. of values = 01 hex

40 + 41

Value = 4396 hex

42

3. parameter value(s)

Value = 0000 hex

44

Format = 08 hex

No. of values = 01 hex

46 + 47

Value = 4416 hex

48

4. parameter value(s)

Value = 0000 hex

50

Information about the parameter request:

● Request reference:

The value is selected at random from the valid value range. The request reference

establishes the relationship between request and response.

● Request ID:

02 hex ––> This identifier is required for a write request.

● Axis:

02 hex ––> The parameters are written to drive 2.

● No. of parameters

04 hex ––> The multi-parameter request comprises 4 individual parameter requests.

1. parameter address ... 4th parameter address

● Attribute:

10 hex ––> The parameter values are to be written.

● No. of elements

01 hex ––> 1 array element is written.

● Parameter number

Specifies the number of the parameter to be written (p1055, p1056, p1058, p1059).