5 thermal motor protection – Efficient Networks Siemens Sinamics S120 User Manual

Page 295

Advertising
background image

Monitoring and protective functions

8.5 Thermal motor protection

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

295

7 

)

U

ุ

U

U



0RWRUVWDOOHG



S  

V

21GHOD\





0RWRUVWDOOHG



6SHHGDGDSWDWLRQVSHHGGHYLDWLRQ



6SHHGWKUHVKROGVWDOOGHWHFWLRQ

PLQS 

S  



(UURUWKUHVKROGVWDOOGHWHFWLRQ

)RUVSHHGFRQWUROZLWKHQFRGHURQO\

6WDOOPRQLWRULQJ

Figure 8-2

Stall protection

Function diagrams (see SINAMICS S List Manual)

● 6730 Current control
● 8012 Torque messages, motor blocked/stalled

Overview of key parameters (see SINAMICS S List Manual)

● r1408 CO/BO: Control status word 3
● p1744 Motor model speed threshold stall detection
● p1745 Motor model fault threshold value stall detection
● p1755 Motor model without encoder, changeover speed
● p1756 Motor model changeover speed hysteresis
● p2178 Motor stalled delay time

8.5

Thermal motor protection

Description

The priority of thermal motor protection is to identify critical situations. If alarm thresholds are

exceeded, the user can set parameterizable response options (p0610) that enable continued

operation (e.g. with reduced power) and prevent immediate shutdown.
● Effective protection is also possible without a temperature sensor (p4100 = 0). The

temperatures of different motor components (stators, core, rotors) can be determined

indirectly using a temperature model.

● Connecting temperature sensors allows the motor temperature to be determined directly.

In this way, accurate start temperatures are available immediately when the motor is

switched on again or after a power failure.